Hi guys,,  i was testing some MPLS TE scenarios, in one of my links i had a
ethernet link like point-to-multipoint.

In this case the tunnel didnt come up,,

the debug outputs are the following

or updating received ERO (error code 2)
R6#
*Dec 20 07:17:39.723: RSVP 131.6.6.6_127->131.4.4.4_10[131.6.6.6]: Received
Path message from 131.6.6.6 (on sender host)
*Dec 20 07:17:39.727: RSVP: new path message passed parsing, continue...
*Dec 20 07:17:39.727: RSVP: Next ERO subobject 131.1.23.2 is strict but not
adjacent
*Dec 20 07:17:39.727: RSVP 131.6.6.6_127->131.4.4.4_10[131.6.6.6]: PATH:
Error updating received ERO (error code 2)
R6#

if  i changed the network type to brodacast the tunnel comes up .


Regards.