Hi guys,, i was testing some MPLS TE scenarios, in one of my links i had a ethernet link like point-to-multipoint.
In this case the tunnel didnt come up,, the debug outputs are the following or updating received ERO (error code 2) R6# *Dec 20 07:17:39.723: RSVP 131.6.6.6_127->131.4.4.4_10[131.6.6.6]: Received Path message from 131.6.6.6 (on sender host) *Dec 20 07:17:39.727: RSVP: new path message passed parsing, continue... *Dec 20 07:17:39.727: RSVP: Next ERO subobject 131.1.23.2 is strict but not adjacent *Dec 20 07:17:39.727: RSVP 131.6.6.6_127->131.4.4.4_10[131.6.6.6]: PATH: Error updating received ERO (error code 2) R6# if i changed the network type to brodacast the tunnel comes up . Regards.
_______________________________________________ For more information regarding industry leading CCIE Lab training, please visit www.ipexpert.com