Question on CME Transcoder values...

 

Is the "sdspfarm units <1-5>" referring to the number of "voice-card"
interfaces that would be used for transcoding?

 

What is the calculation used to determine how many sessions you can
configure for "extra" DSP channels...Say you have three PVDM-12's and a
four channel PRI in the router...I think I recall hearing from one of
the bootcamps that the Transcoder uses two channels per session?  If so,
would the calculation be...36 channels total minus four for the PRI,
leaving 32 and divide by two, resulting in 16 sessions?

 

Thanks,

Kevin

 

Kevin Porter
Systems Engineer L4

Netelligent Corporation
400 South Woods Mill Drive, Suite 105
St. Louis, MO 63017

Office: (314) 392-6921
Cell: (314) 852-1252
Fax: (314) 392-9760

[EMAIL PROTECTED]
www.netelligent.com
Bridging The Gap Between Good and GREAT IP Communications!

 

Reply via email to