Question on CME Transcoder values...
Is the "sdspfarm units <1-5>" referring to the number of "voice-card" interfaces that would be used for transcoding? What is the calculation used to determine how many sessions you can configure for "extra" DSP channels...Say you have three PVDM-12's and a four channel PRI in the router...I think I recall hearing from one of the bootcamps that the Transcoder uses two channels per session? If so, would the calculation be...36 channels total minus four for the PRI, leaving 32 and divide by two, resulting in 16 sessions? Thanks, Kevin Kevin Porter Systems Engineer L4 Netelligent Corporation 400 South Woods Mill Drive, Suite 105 St. Louis, MO 63017 Office: (314) 392-6921 Cell: (314) 852-1252 Fax: (314) 392-9760 [EMAIL PROTECTED] www.netelligent.com Bridging The Gap Between Good and GREAT IP Communications!