You can have a data T1 and a PRI T1, or a data E1 and a PRI E1, but you can't 
split T1/E1 across the same card. 

On Jul 9, 2010, at 7:05 AM, Kevin Damisch wrote:

> I’ve seen this question before but can’t find it.  On a VWIC2-2MFT-T1/E1 
> card, can you configure or are there issues with having  a data T1 on one 
> port and an E1 PRI on the other port on the same card?  I thought the VWIC2 
> cards supported that, but not the older ones.
> 