You could do a "debug ccsip messages" on the CUBE and see what's taking place 
in the SIP messages between the gateway and CUCM.  Send that on over for us to 
take a look at.

Matthew Berry
Sr. Voice Engineer - CCIE 26721
[cid:CB259CF6-BDEC-4D6C-AE3F-AC1ADFE83021]<http://www.cdw.com/content/services/advanced-technology/default.aspx>

CDW Advanced Technology Services
7145 Boone Avenue North | Brooklyn Park, MN 55428
Single Number Reach: +1.763.592.5987
[email protected]


From: "[email protected]<mailto:[email protected]>" 
<[email protected]<mailto:[email protected]>>
Date: Fri, 31 Dec 2010 08:59:20 -0600
To: "[email protected]<mailto:[email protected]>" 
<[email protected]<mailto:[email protected]>>
Subject: [OSL | CCIE_Voice] Inbound SIP call to CUCM from CUBE goes unanswered

I'm testing a cube configuration in my lab setup.
I have H.323 coming from CME to CUBE running on R1 and then SIP to the CUCM via 
a SIP trunk.
I see the proper dialpeers being triggered in CUBE, but the CUCM doesn't seem 
to respond to the SIP call setup inbound.

Calls from CUCM to CME via CUBE work , so I'm pretty confident the SIP trunk is 
functional.

Short of trying to look through CUCM traces, is there a good debug on R1/Cube 
that would provide some insight into whats going on?