The map-class is the workaround and as far as I know the bandwidth command
wont work.

Regards,
Roger Carpio.

On Tue, Jun 14, 2011 at 6:02 PM, Bill Lake <whl...@gmail.com> wrote:

> I think if you set the bandwidth to greater than 768 you will not have this
> applied to the interface for BR2
>
> On Tue, Jun 14, 2011 at 5:17 PM, Roig Borrell, Francesc Xavier <
> francesc.ro...@tecnocom.es> wrote:
>
>>  Hi all,
>>
>>
>>
>> If in the exam in Qos WAN exercise were asked to configure MLF or FR12
>> between HQ and SB, supposing there is only one physical interface in HQ, the
>> traffic shaping applied will affect the BR2 subintertace  appliying a
>> default mincir 28000 which is a problem for more than one call
>>
>>
>>
>>
>>
>> HQ#sh frame-relay pvc 102
>>
>>
>>
>>     cir 56000     bc 7000      be 0         byte limit 875    interval 125
>>
>>
>>   mincir 28000     byte increment 875   Adaptive Shaping none
>>
>>   pkts 533       bytes 168144    pkts delayed 526       bytes delayed
>> 166528
>>
>>   shaping active
>>
>>   traffic shaping drops 0
>>
>>   Queueing strategy: fifo
>>
>>   Output queue 39/40, 56 drop, 531 dequeued
>>
>> HQ#
>>
>>
>>
>> Should we create this specific class map for BR2 as a workaround, or
>> shouldn’t we do anything because nothing has been required for BR2 and we
>> would breaking a requirement?
>>
>>
>>
>> map-class frame-relay BR2
>>
>>  frame-relay cir 1536000
>>
>>  frame-relay bc 15360
>>
>>  frame-relay be 0
>>
>>  frame-relay mincir  1536000
>>
>>
>>
>>
>>
>> Which would be the right answer? What do you think?
>>
>>
>>
>> Thanks in advance! Regards
>>
>> Francesc
>>
>>
>>
>>
>>
>>
>>
>> Francesc Xavier Roig Borrell
>>
>> Network Senior Consultant
>>
>> Integración de Sistemas y Tecnología
>>
>> C/Santander, 49-51
>>
>> Barcelona 08020
>>
>> Tel. Fijo: (+34) 934965108 ext 64697
>>
>> Tel. Móvil / Fax: (+34) 647 32 21 55 (24697) / (+34) 934965161
>>
>> email: francesc.ro...@tecnocom.es
>>
>> http://www.tecnocom.es
>>
>>
>>
>> *Por favor, antes de imprimir este mensaje, asegúrate de que es
>> necesario. Ayudemos a cuidar el medio ambiente*
>>
>> *Este mensaje puede contener información confidencial o privilegiada. Si
>> le ha llegado por error, rogamos no haga uso del mismo, avise al remitente y
>> bórrelo. **Consulte **aviso 
>> legal<http://www.tecnocom.es/Paginas/InformacionLegal.aspx>
>> *
>> *This message may contain confidential or privileged information. If it
>> has been sent to you in error, please do not use it, notify the sender of
>> the error and delete it. **See **legal 
>> notice<http://www.tecnocom.es/sites/en/Paginas/InformacionLegal.aspx>
>> *
>>
>>
>>
>> _______________________________________________
>> For more information regarding industry leading CCIE Lab training, please
>> visit www.ipexpert.com
>>
>> Are you a CCNP or CCIE and looking for a job? Check out
>> www.PlatinumPlacement.com
>>
>
>
> _______________________________________________
> For more information regarding industry leading CCIE Lab training, please
> visit www.ipexpert.com
>
> Are you a CCNP or CCIE and looking for a job? Check out
> www.PlatinumPlacement.com
>

<<image001.jpg>>

_______________________________________________
For more information regarding industry leading CCIE Lab training, please visit 
www.ipexpert.com

Are you a CCNP or CCIE and looking for a job? Check out 
www.PlatinumPlacement.com

Reply via email to