Hello All,

The solution for my issue was both the H323 trunk and Gatekeeper controlled 
trunk should have the significant digits as 4 for the inbound calls.

And the Gatekeeper controlled trunk should have "Enable Inbound Faststart". 


Thanks Ryan for the hint, the only change I did was on the Gatekeeper 
controlled trunk instead of H323GW. When I did that on H323GW the issue was 
there so just tried it on the Gatekeeper controlled trunk and removed it on the 
H323GW, it started working.


Thanks,
Viki



________________________________
 From: Ryan Maxam <ryan.ma...@gmail.com>
To: vignesh sethuraman <sethuvign...@yahoo.co.in> 
Cc: "ccie_voice@onlinestudylist.com" <ccie_voice@onlinestudylist.com> 
Sent: Tuesday, 5 February 2013 8:25 PM
Subject: Re: [OSL | CCIE_Voice] CCIE Voice - IPX Vol1 - Lab 4A - Task 4.7
 

I ran into this same problem.  if you check "Enable Inbound FastStart" on you 
H323 gateway that should correct the problem.  Its caused because you are 
communicating between a SIP trunk and an H323 trunk.  

On Tuesday, February 5, 2013, vignesh sethuraman  wrote:

Hello,
>
>
>In the task 4.7 of IPX Vol1 Lab 4A, am able to call and answer the calls to 
>BR2 from HQ and BR1. 
>
>
>But when I dial HQ phones or BR1 phones from BR2, am getting a ring back tone 
>but I could not answer the calls. Even after picking the handset, I could hear 
>the ringback on the BR2 phones.
>
>
>I have kept the significant digits as 4 on both the CME (H.323GW) trunk and 
>Gatekeeper controlled trunk.
>
>
>Could you please someone help to resolve this.
>
>
>Thanks,
>Viki
_______________________________________________
For more information regarding industry leading CCIE Lab training, please visit 
www.ipexpert.com

Are you a CCNP or CCIE and looking for a job? Check out 
www.PlatinumPlacement.com

Reply via email to