Check if your transcoder profile has codec g729r8 added,its not there by default.
On Thu, Dec 12, 2013 at 12:55 PM, aman sinha <[email protected]> wrote: > Thanks, > Found problem - sdspfarm transcode sessions 2 > was missing in telephony-services. > > > On Thu, Dec 12, 2013 at 12:53 PM, aman sinha <[email protected]> wrote: > >> This is codec negotiation issue. Transcoder is not is not working. >> HQ to Site C is g729ulaw, while CUE uses G711ulaw. >> >> I verified by using G711ulaw between HQ and SiteC. Everything worked fine. >> >> What did I miss in transcoder? >> >> >> On Thu, Dec 12, 2013 at 12:28 PM, aman sinha <[email protected]> wrote: >> >>> I have this same issue. >>> >>> Any solutions ? What am I missing ? >>> >>> http://www.voiceie.com/cgi-bin/ultimatebb.cgi?ubb=get_topic;f=8;t=002216 >>> >>> >>> Regards, >>> Aman >>> >> >> > > _______________________________________________ > Free CCIE R&S, Collaboration, Data Center, Wireless & Security Videos :: > > iPexpert on YouTube: www.youtube.com/ipexpertinc >
_______________________________________________ Free CCIE R&S, Collaboration, Data Center, Wireless & Security Videos :: iPexpert on YouTube: www.youtube.com/ipexpertinc