Hi George

Happy new year to everybody on the study list!

On your blog I found this page: 
http://www.my80211.com/cisco-wlc-labs/2009/10/30/what-you-need-to-know-about-tx-power-and-80211a-5ghz-on-a-ci.html

There you say that the following concerning the power levels (only FCC):

UNII-1 max 11dBm
UNII-2 and UNII-3 max 17dBm

Now I found another page: http://www.air802.com/fcc-rules-and-regulations.html

There they say the following (only FCC, see row Point-to-MultiPoint Intentional 
Radiator Power @ FCC 5 GHz BANDS AND RULES):

UNII-1 max 16dBm
UNII-2 max 23dBm
UNII-2 Extended max 23dBm
UNII-3 max 29dBm

Im from Europe, so now I am not sure what is correct or if the WLC is not 
allowing the max values defined by the FCC. It would help me a lot, if you can 
correct me ;-)

Thanks and regards
Dominic
_______________________________________________
For more information regarding industry leading CCIE Lab training, please visit 
www.ipexpert.com

Reply via email to