A new student showed me how to build in Coot the other day and I was impressed enough to spend three hours trying to install it on my laptop. Works great, but I'm a little confused by the inconsistent electron density. In Coot, some water molecules don't have any 2Fo-Fc density around them; in O, most of them have density although most are pretty marginal.

So, which program is right? I assume they're calculating the distribution of electron density, or else the default cutoff means something different in each. I had thought everyone used 1 sigma, with some standard formula for calculating this, but obviously that's not the case. What should I go by in deciding whether to kill the waters?

thanks,
Nat

Your question should maybe be posted to [EMAIL PROTECTED], but you already have the solution to your "problem" the different contour levels. You should also have a look at the validation tools in Coot, there's an optio to validate waters.

Juergen



--
--------------------------------------------
Jürgen Bosch
University of Washington
STRUCTURAL GENOMICS OF PATHOGENIC PROTOZOA
Health Science Building
Dept. of Biochemistry, K-418
Box 357742
1705 NE Pacific Street
Seattle, WA 98195-7742
Phone:   206-616-4542
FAX:     206-685-7002
Web:     www.sgpp.org