***  For details on how to be removed from this list visit the  ***
***          CCP4 home page http://www.ccp4.ac.uk         ***


Hi Raaijmakers,
Thanks for warning me, but it isnt seems to be the case.
Fred


ATOM 5309 CD GLN B 382 76.188 11.378 1.201 1.00 50.01 C ATOM 5310 OE1 GLN B 382 76.111 12.097 2.198 1.00 52.69 O ATOM 5311 NE2 GLN B 382 77.109 11.558 0.255 1.00 49.52 N ATOM 5312 C GLN B 382 76.659 6.987 2.615 1.00 47.47 C ATOM 5313 O GLN B 382 77.021 7.249 3.769 1.00 47.66 O ATOM 5314 OXT GLN B 382 76.446 5.811 2.311 1.00 47.85 O
TER              GLN B 382
ATOM 5315 P PO4 501 27.525 23.409 31.967 1.00 50.13 P ATOM 5316 O1 PO4 501 28.038 24.716 31.401 1.00 49.18 O ATOM 5317 O2 PO4 501 26.636 22.855 30.888 1.00 48.70 O ATOM 5318 O3 PO4 501 28.643 22.487 32.388 1.00 47.10 O ATOM 5319 O4 PO4 501 26.774 23.648 33.256 1.00 50.36 O ATOM 5320 P PO4 502 49.903 24.557 -0.380 1.00 60.00 P ATOM 5321 O1 PO4 502 50.639 23.803 -1.462 1.00 55.67 O ATOM 5322 O2 PO4 502 49.366 25.818 -1.048 1.00 60.48 O ATOM 5323 O3 PO4 502 48.735 23.741 0.108 1.00 57.80 O ATOM 5324 O4 PO4 502 50.748 24.941 0.812 1.00 56.76 O HETATM 5325 CS CS 601 34.382 10.471 47.379 1.00 20.00 CS HETATM 5326 CS CS 602 46.044 9.927 -13.641 1.00 20.00 CS HETATM 5327 CS CS 603 30.618 14.930 32.142 1.00 20.00 CS

H. Raaijmakers wrote:

Just to make sure, you are using the right columns are you? the s of Cs
should be aligned with the C of carbon or I of iodine in the pdb.
otherwise refmac might believe it is a carbon atom.

cheers,

Hans


Frederico Moraes Ferreira wrote:
***  For details on how to be removed from this list visit the  ***
***          CCP4 home page http://www.ccp4.ac.uk         ***


I dont think so. It seems to be related to the cesium library or
something. Changing the PDB cesium cards to iodine makes refmac5 to work
in order with no complains at all. Does it make sense?
thanx,
Fred


Eleanor Dodson wrote:

I have never seen this message but suspect it means what it says - too
many VDW contacts..
Things to check: 1) run the pdb through Structure analysis - analyse
molecular contacts to find where the clashes are.  Maybe the CRYST1
card got corrupted while you were editing the file and the SG is not
correct?

After that you will have to wait for Garib to come back from Barcelona..
Eleanor



Frederico Moraes Ferreira wrote:

***  For details on how to be removed from this list visit the  ***
***          CCP4 home page http://www.ccp4.ac.uk         ***


Hi List,
Im struggling with the following REFMAC error message:

...

***TLS refinement cycle***    1

358441 8683 358440 80000 11948 36270
Too many vdw contacts
Check symmetry, cell and molecular replacement solution
===> Error: FIND_CONTACT_WITH_BRICKING failed
<B><FONT COLOR="#FF0000"><!--SUMMARY_BEGIN-->
Refmac_5.2.0005:  FIND_CONTACT_WITH_BRICKING failed
Times: User:      56.2s System:    2.0s Elapsed:     0:59
</pre>
</html>
<!--SUMMARY_END-->
...

This error raises when I put few, say 10, cesium sites on my
coordinate file.  Noting happens when I play with NONbonding sigmas.
Please, could someone give me a clue?
All the best,
Fred






Reply via email to