Can you tell me what is in a CNS density modified file?
Eleanor
You may need to CAD together the original Fobs SIGFobs with the CNS
output after conversion to MTZ

See Reflections utilities in the GUI
Eleanor

pengpeng hao wrote:

>***  For details on how to be removed from this list visit the  ***
>***          CCP4 home page http://www.ccp4.ac.uk         ***
>
>
>Dear All
>
>I got a trouble!!!
>
>I have read the message 'how to convert CNS density modified file to mtz 
>forarp/warp' from ccp4bb, it is quite useful, and now I have successfully 
>convert .hkl to .mtz.(the method I used is SAD)
>
>But when I do auto-build in the ARP, I got trouble! 
>
>in the ARP, there are 4 labels: 'Fobs, Sigma, PHIB, FOM'. 
>But in my .mtz file I cannt find 'Sigma', and when I run the program, I was 
>told that the label of 'Sigma' should be added. So could you tell me what 
>should I do and where I can find 'Sigma'? (I can't find standard deviation at 
>.hkl file coming from density modification as well)
>
>Thank you very much!!!
>
>Best
>Hao
>
>_________________________________________________________________
>率先尝试 Windows Live Mail。
>http://ideas.live.com/programpage.aspx?versionId=5d21c51a-b161-4314-9b0e-4911fb2b2e6d
>
>
>  
>