Is there a symmetry clash or some such serious error? When the geometry explodes like this it is worth reading the log file carefully to see what geometric problems are listed with the input coordinates.

Eleanor

Mario Sanches wrote:

***  For details on how to be removed from this list visit the  ***
***          CCP4 home page http://www.ccp4.ac.uk         ***


Dear all,

I am refining a low resolution structure (3.0A) in refmac. The problem is that no matter which value I choose for matrix weight the RMSD for bonds stays higher than 0.3A (yes, I didn't mistype it, it is really 0.3A). I have tried matrix weight as low as 0.01 and also AUTO.

Since there is two subunits in the assymetric unit I am refining using NCS. I also tried turning it off but the problem persists. The coordinate file I entered to refmac came from CNS were I had no problem with geometry. Since refmac has some advantages (like TLS refinement) I always try to change to refmac at the end of the refinement.

Is there something I am missing? Thanks in advance for all kind of suggestions,