*** For details on how to be removed from this list visit the *** *** CCP4 home page http://www.ccp4.ac.uk ***
All - small question about running Phaser. I'm running the Brute Translation Function with 1 molecule (no fixed solution). The data was indexed as P21212 & I want to try various other space groups in PG222, so I inserted the lines in the normal BTF script: SGAL TEST P2122 SGAL TEST P2212 SGAL TEST P222 each in a separate job. So far it's done about 20% of the job in each case and the outputs are identical (apart obviously from the echo of the SGAL line, filenames & times). Shouldn't I be seeing different intermediate results (peak heights & positions) from the translation functions? I assume I've got the format right because specifying space groups such as 'P 21 2 2' or 1017 gives an error, or is the order important (doc doesn't say). Or am I being impatient & I have to wait until the jobs finish? Cheers -- Ian ******************************************** Ian J. Tickle, DPhil. Director of X-ray Technology Astex Therapeutics Ltd 436 Cambridge Science Park Milton Road, Cambridge CB4 0QA, UK Tel: +44(0)1223 226214 Fax: +44(0)1223 226201 www.astex-therapeutics.com Disclaimer This communication is confidential and may contain privileged information intended solely for the named addressee(s). It may not be used or disclosed except for the purpose for which it has been sent. If you are not the intended recipient you must not review, use, disclose, copy, distribute or take any action in reliance upon it. If you have received this communication in error, please notify Astex Therapeutics Ltd by emailing [EMAIL PROTECTED] and destroy all copies of the message and any attached documents. Astex Therapeutics Ltd monitors, controls and protects all its messaging traffic in compliance with its corporate email policy. The Company accepts no liability or responsibility for any onward transmission or use of emails and attachments having left the Astex Therapeutics domain. Unless expressly stated, opinions in this message are those of the individual sender and not of Astex Therapeutics Ltd. The recipient should check this email and any attachments for the presence of computer viruses. Astex Therapeutics Ltd accepts no liability for damage caused by any virus transmitted by this email. E-mail is susceptible to data corruption, interception, unauthorized amendment, and tampering, Astex Therapeutics Ltd only send and receive e-mails on the basis that the Company is not liable for any such alteration or any consequences thereof.