Hi,

You can read both files back into scalepack and scale them. Better still, if you have the .x files from denzo, read both sets into scalepack. Scenarios both in the manual.

Johan

yang li wrote:
Hi:
I have two set of data from the same crystal with the names 1.sca and 2.sca,
they have different Intensity values due to different scale factors.
Now I use Scalepack2mtz
convert them to 1.mtz and 2.mtz, then use cad to merge to a cad.mtz, then
convert it to cad.sca file, I find that the Intensity values in this
cad.sca arediffrent from
1.sca and 2.sca, I wonder if the program has scaled the values itself?
If that is true,
which program did this, Scalepack2mtz or cad?
Thanks!

Li Yang



--
+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
Dr. Johan P. Turkenburg                     X-ray facilities manager
York Structural Biology Laboratory      
Chemistry Department                        Phone (+) 44 1904 328253
University of York                          Fax   (+) 44 1904 328266
York YO10 5YW   UK                          Email: [EMAIL PROTECTED]
+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++

Reply via email to