Huiying Li wrote:
I tried to scale, using SCALA through CCP4i GUI, three blocks of data collected with one crystal (3 mtz files output from MOSFLM). The GUI has only one MTZ input slot. Which program can be used to combine the 3 unmerged mtz files together? CAD refused to handle these raw mtz files.

Thanks in advance for any help.

Huiying

Using the CCP4 GUI, employ the following steps:

1. Open a Sort/Modify/Combine job and renumber your data sets (reset batch numbers option). A simple method is to add 1000 to the batch numbers for one data set and 2000 to the batch numbers for the second data set (assuming you have less than 999 frames of data output from MOSFLM.)

2. Open another Sort/Modify/Combine job and combine the renumbered MTZ files into one merged file. Click on Add File to add additional renumbered batches from step 1. Each batch of reflections will now have unique batch numbers.

3. Open a Scale and Merge Intensities task window. Select as your input the sorted and combined file output from step 2. In the Define Datasets section, choose Combine All Input Datasets into a Single Output Dataset. You can convert the scaled intensities to structure factors by checking the appropriate box. The combined datasets will not have monotonically varying R(merge) values across batches (1-1000, 1001-2000, 2001-3000) becuase of discontinuities in the data. However the merged datasets should have good overall statistics if appropriate for merging.

Cheers,


--
------------------------------------------------------------------------
Roger S. Rowlett
Professor
Colgate University Presidential Scholar
Department of Chemistry
Colgate University
13 Oak Drive
Hamilton, NY 13346

tel: (315)-228-7245
ofc: (315)-228-7395
fax: (315)-228-7935
email: [EMAIL PROTECTED]