It is recorded by SCALA - if you use that data processing procedure.
You can still do a run of scala after SCALEPACK or XDS or whatever providing you output integrated, unmerged intensities.
You are right though - we need a data analysias tool.. Eleanor James Pauff wrote:
Hello all, Silly question, but what is the most convenient means to find the overall I/sigma and the I/sigma for the highest resolution shell in CCP4? At the end of refinement and validation, and after running PROCHECK, I am still using a very convoluted route to obtaining these numbers. Thanks! JMP ____________________________________________________________________________________You rock. That's why Blockbuster's offering you one month of Blockbuster Total Access, No Cost. http://tc.deals.yahoo.com/tc/blockbuster/text5.com