You almost certainly have a wrong format statement - it is tricky getting them correct for more complex cns inputs.
Eleanor

Miller, Mitchell D. wrote:
You could also try cns2mtz?
http://www.ysbl.york.ac.uk/~cowtan/cns2mtz/cns2mtz.html Regards, Mitch
-----Original Message-----
From: CCP4 bulletin board [mailto:[EMAIL PROTECTED] On Behalf Of Ezra Peisach
Sent: Thursday, July 03, 2008 11:28 AM
To: [email protected]
Subject: Re: [ccp4bb] Parameter MAXSAVE exceeded

I do not know off hand what a .cv file is - unless it is a cns/xplor reflection file. Instead of using f2mtz - try sftools.

Ezra

Jayashankar wrote:
Dear scientists and friends,

When I try to convert a .cv file to .mtz by f2mtz I got the following error,what it means ans what should I do to get rid of it.

''Parameter MAXSAVE exceeded''

--
S.Jayashankar
Research Student
Institute for Biophysical Chemistry
Hannover Medical School
Germany



Reply via email to