Oops, yes. Element symbol right-justified in 77-78, charge in 79-80. Out
of curiosity, shouldn't "CL " technically be listed as "CL-1" in the
PDB file for Refmac as well?
Cheers,
Roger Rowlett
Ian Tickle wrote:
Hi, it's not clear why this should be necessary in general since
$CLIBD/atomsf.lib contains entries for both Zn & Zn+2:
Zn
30 30 1.304100
14.074300 7.031800 5.162500 2.410000
3.265500 0.233300 10.316299 58.709702
-1.612000 0.678000 0.222000 1.431000
Zn+2
30 28 0.780700
11.971900 7.386200 6.466800 1.394000
2.994600 0.203100 7.082600 18.099499
-1.612000 0.678000 0.222000 1.431000
Nevertheless in this particular the ionised form is no doubt more
appropriate than the elemental one.
But anyway shouldn't the atomic symbols go in cols 77-80, not 72-75?
i.e.:
123456789012345678901234567890123456789012345678901234567890123456789012
34567890
ATOM 3048 CLBB DRG X 1 1.461 37.707 15.068 1.00 37.36
CL
ATOM 3155 O HOH H 318 -2.609 36.139 -25.338 1.00 48.47
O
HETATM 3156 ZN ZN A 981 4.451 8.580 3.686 1.00 31.06
ZN+2
Cheers
-- Ian
-----Original Message-----
From: [EMAIL PROTECTED]
[mailto:[EMAIL PROTECTED] On Behalf Of Roger Rowlett
Sent: 11 September 2008 14:37
To: Patrick Loll
Cc: [email protected]
Subject: Re: [ccp4bb] specifying metal ion names in PDB file
Patrick,
Zinc ions should be identified as ZN+2 at the end of the line
for Refmac
(see modified line below):
12345678901234567890123456789012345678901234567890123456789012
345678901234567890
ATOM 3048 CLBB DRG X 1 1.461 37.707 15.068 1.00
37.36 CL
ATOM 3155 O HOH H 318 -2.609 36.139 -25.338 1.00
48.47 O
HETATM 3156 ZN ZN A 981 4.451 8.580 3.686 1.00
31.06 ZN+2
Cheers,
--
--------------------------------------------------------------
----------
Roger S. Rowlett
Professor
Colgate University Presidential Scholar
Department of Chemistry
Colgate University
13 Oak Drive
Hamilton, NY 13346
tel: (315)-228-7245
ofc: (315)-228-7395
fax: (315)-228-7935
email: [EMAIL PROTECTED]
Patrick Loll wrote:
Hi,
I know this has been covered ad infinitum, yet we find ourselves
unable to get Refmac to recognize a zinc ion in the PDB file.
12345678901234567890123456789012345678901234567890123456789012
345678901234567890
ATOM 3048 CLBB DRG X 1 1.461 37.707 15.068
1.00 37.36 CL
ATOM 3155 O HOH H 318 -2.609 36.139 -25.338
1.00 48.47 O
HETATM 3156 ZN ZN A 981 4.451 8.580 3.686
1.00 31.06 ZN+2
The chlorine in the above example is read properly, but the
zinc is not:
FORMATTED OLD file opened on unit 45
Logical name: ATOMSF,
Filename: /sw/share/xtal/ccp4-6.0.2/lib/data/atomsf.lib
No match for atom ID ZN subtracting one character
No match for atom ID Z giving up!
Note that the register of the atom name appears correct.
We've tried
a zillion permutations including using ATOM/HETATM, moving
the residue
name so it's left-justified, playing with the position of the name
over in columns 70-72, using Zn instead of ZN,...
Any words of wisdom? It's embarrassing to be hung up on
something so
simple and obvious, yet hung up we are.
Pat
--------------------------------------------------------------
-------------------------
Patrick J. Loll, Ph. D.
Professor of Biochemistry & Molecular Biology
Director, Biochemistry Graduate Program
Drexel University College of Medicine
Room 10-102 New College Building
245 N. 15th St., Mailstop 497
Philadelphia, PA 19102-1192 USA
(215) 762-7706
[EMAIL PROTECTED] <mailto:[EMAIL PROTECTED]>
Disclaimer
This communication is confidential and may contain privileged information
intended solely for the named addressee(s). It may not be used or disclosed
except for the purpose for which it has been sent. If you are not the intended
recipient you must not review, use, disclose, copy, distribute or take any
action in reliance upon it. If you have received this communication in error,
please notify Astex Therapeutics Ltd by emailing [EMAIL PROTECTED] and destroy
all copies of the message and any attached documents.
Astex Therapeutics Ltd monitors, controls and protects all its messaging
traffic in compliance with its corporate email policy. The Company accepts no
liability or responsibility for any onward transmission or use of emails and
attachments having left the Astex Therapeutics domain. Unless expressly
stated, opinions in this message are those of the individual sender and not of
Astex Therapeutics Ltd. The recipient should check this email and any
attachments for the presence of computer viruses. Astex Therapeutics Ltd
accepts no liability for damage caused by any virus transmitted by this email.
E-mail is susceptible to data corruption, interception, unauthorized amendment,
and tampering, Astex Therapeutics Ltd only send and receive e-mails on the
basis that the Company is not liable for any such alteration or any
consequences thereof.
Astex Therapeutics Ltd., Registered in England at 436 Cambridge Science Park,
Cambridge CB4 0QA under number 3751674