Dear all, When refining a DNA-structure (poor data, resolution 2.5) and using ARP/wARP Solvent 7.0.1. for water divining with CCP4 6.1.1 and GUI 2.0.4, I get the following error:
QUITTING ... ARP/wARP module stopped with an error message: ARP_WARP_MODE_WILSON When checking the "warp_wilson_log" file, I get: Comments: Overall fit of the data to the Wilson curve: Comments: Problems Resolution range 5.15 to 4.89 Comments: Problems Resolution range 4.89 to 4.67 Comments: Problems Resolution range 2.89 to 2.84 Comments: Possible reasons - missing overloads Solvent content 1.00 Computed solvent content is too high - check your input ***** ERROR ***** I was kind of surprised, because with the same data! and an older version of ARP/wARP, which was integrated in the Refmac5 program, I did not get any errors of this kind..!? Is there a way to circumvent this please..? Many thanks Kristof Van Hecke Disclaimer: http://www.kuleuven.be/cwis/email_disclaimer.htm