The paper Acta Cryst. D59 (2003) 2125-2132 discusses searching for 
disulfides. In general this works for data truncated for phasing to
between 2.1 and 2.9 A. If the resoltuions is higher than 2.1, you
can search for individual sulfurs, if it is worse than 2.9 even 
fitting them as disulfides is unreliable and they have to be
treated as 'super-sulfurs'. The main advantage of incorporating
disulfides in this resolution range is that the resulting 
experimental phases extend better to higher resolution.

George

Prof. George M. Sheldrick FRS
Dept. Structural Chemistry,
University of Goettingen,
Tammannstr. 4,
D37077 Goettingen, Germany
Tel. +49-551-39-3021 or -3068
Fax. +49-551-39-22582


On Mon, 10 Aug 2009, Francis E Reyes wrote:

> Hi all
> 
> Has there been any work/reports of using disulfide restraints (number of heavy
> atoms as well as distance) for heavy atom searching/scoring for anomalous
> sulfur phasing?
> 
> What resolution range would this be most effective?
> 
> Thanks
> 
> FR
> 
> 
> ---------------------------------------------