If I were to deal with your example, I would look into distance
profile between residues in coordinate section, which then
gives answer to your question.
OK that's interesting, I hadn't realised that the interatomic distances
played an active role in determining connectivity: I had assumed the
whole point of the various connectivity specifiers was to avoid reliance
on distance calculations.
yes where distances are unreliable or where you cannot unambiguously
determine the link point, e.g. when it's apriori unclear which atom
is leaving upon linking, how many hydrogens are involved etc.
But resolution of the kind of ambiguity I
illustrated would not occur automatically, or would it? - i.e. would the
need for it only become clear when the structure was checked manually?
I think this depends on the quality of your data. If you have a remote
model and poor resolution then the difficulties arise. You do not LINKR
everything, or do you? If two atoms may be automatically referenced
in a residue, the same can be done for the mainchain, so I would think
that one uses LINKR when things are not self-obvious from structural
positions.
Of course it makes sense to use distance information for fully-refined
structures such as those that are (hopefully!) deposited with the PDB,
but it would be more of an issue with refinement programs that have to
deal with all kinds of errant input geometry! I suppose the fundamental
problem is that we're trying to use the same format for both purposes
and there are fundamentally conflicting requirements.
Probably that's why there are LINKs and LINKRs I guess.
Regards,
Eugene.
Cheers
-- Ian
Disclaimer
This communication is confidential and may contain privileged information
intended solely for the named addressee(s). It may not be used or disclosed
except for the purpose for which it has been sent. If you are not the intended
recipient you must not review, use, disclose, copy, distribute or take any
action in reliance upon it. If you have received this communication in error,
please notify Astex Therapeutics Ltd by emailing
[email protected] and destroy all copies of the message and any
attached documents.
Astex Therapeutics Ltd monitors, controls and protects all its messaging
traffic in compliance with its corporate email policy. The Company accepts no
liability or responsibility for any onward transmission or use of emails and
attachments having left the Astex Therapeutics domain. Unless expressly
stated, opinions in this message are those of the individual sender and not of
Astex Therapeutics Ltd. The recipient should check this email and any
attachments for the presence of computer viruses. Astex Therapeutics Ltd
accepts no liability for damage caused by any virus transmitted by this email.
E-mail is susceptible to data corruption, interception, unauthorized amendment,
and tampering, Astex Therapeutics Ltd only send and receive e-mails on the
basis that the Company is not liable for any such alteration or any
consequences thereof.
Astex Therapeutics Ltd., Registered in England at 436 Cambridge Science Park,
Cambridge CB4 0QA under number 3751674