Actually I think it needs the labels   FWT PHWT

I may be wrong but like REFMAC I think it outputs a ositive FWT and PHWT is either equal to PHIC or to PHHIC+180, depending on the sign og
FWT = (2m|Fo| - D|Fc|)


Eleanor


Hailiang Zhang wrote:
Dear Tim:

This is also what I thought. Thanks!

Best Regards, Hailiang


Dear Hailiang,

the man-page of sigmaa claims
              FWT (2m|Fo| - D|Fc|) exp(i AlphaCalc)
                      Analogous to 2Fo-Fc map, FFT input: F1=FWT PHI=PHIC
                                               ^^^^^^^^^^^^^^^^^^^^^^^^^^
so I would leave out WCMB.

Tim

On Tue, Aug 10, 2010 at 01:33:11PM -0400, Hailiang Zhang wrote:
Hi there:

When I generate the mtz file by SIGMAA, and want to view the 2mFo-DFc
map
in coot, should I choose "FWT PHIC WCMB" combination or just "FWT PHIC"?
I
think the later is more reasonable and I did see somebody the former as
well. Didn't see explicit instruction in SIGMAA document, and I
appreciate
for any hint.

Best Regards, Hailiang
--
--
Tim Gruene
Institut fuer anorganische Chemie
Tammannstr. 4
D-37077 Goettingen

GPG Key ID = A46BEE1A


Reply via email to