On 27 Aug 2010, at 10:55, Petr Kolenko wrote:

> Dear crystallographers,
> 
> I have a structure at 3.3A resolution, 16 identical chains in AU, merohedral 
> twinning present. I started to refine using NCS restraints with chain A as a 
> reference chain. Current Rwork/Rfree is 21/25. There is almost nothing to 
> refine manually in whole structure now. But, refinement without NCS 
> restraints results in Rwork/Rfree of about 17/28. What should I do? Or is it 
> possible to deposit the structure refined using NCS restraints in final 
> refinement?

This seems like a really well-done NCS refinement; using the multi-fold NCS is 
allowing you to get what is an excellent Rfree and Rwork-Rfree gap for 3.3A 
data.  Definitely deposit the NCS-restrained version; refining without NCS 
restraints just increases the number of parameters by a factor sixteen and 
spends most of those on fitting noise.

1% Ramachandran outliers at 3.3A also seems entirely reasonable.

Tom