It seems that your mtz doesn't have the map coefficients on it,  that is why
it is failing. Check if it has the columns FWT PHWT.. If it doesn't them
coot will not automatically recognize it.  A simple solution would be to run
a cycle of rigid body refinement in Refmac and use the output mtz as the
input for coot. The Refmac mtz will have the map coefficient columns on it.

Good luck,

Mario Sanches



2011/3/7 王瑞 <[email protected]>

> I have an ambiguous question that can't decide where it belongs . In fact,
> I was going to refine my data after molecular replacement, but coot can't
> read them. The mtz file was converted from a sca file by using " Import
> Merged Data in ccp4".A screenshot is attached.




-- 