To add to Ed's comments:
Find someone in the immediate department/area to walk you through your first structure. But to answer your question: What about the MR didn't work? Use your MR model to find your heavy atoms. They can be found using anomalous data difference fouriers (or even better log likelihood gradient maps) using data as low as 6-8A, and, in my case, using a model that was about 50% (mass) of the ASU with the placement of that 50% to be about 80-90% correct. F On Mar 30, 2012, at 7:34 AM, Shanti Pal Gangwar wrote: > Dear all > > I am beginner in crystallography.We have collected a native data of a given > protein at 2.2A resolution but are unable t solve by MR > therefore we collected Hg, and Pt derivative after soaking the crystals. I > don't know how to process this heavy atom derivative data > and find the anomalous signal if heavy atom is there? > > thanks in advance for help and suggestions.. > > > > > > regards > > Shanti Pal Gangwar > > > > --------------------------------------------- Francis E. Reyes M.Sc. 215 UCB University of Colorado at Boulder