Sita Ram Meena <[email protected]> writes:

>    Hello everyone
>     I Was trying to convert my mtz output of the SCALA to CNS format in
>    mtz2various but its gives some error
>    please look at log file ................

[...]

>     Data line--- OUTPUT CNS
>     Data line--- labin  FP=F_New SIGFP=SIGF_New FPH=F_New SIGFPH=SIGF_New
>    DP=DANO_New SIGDP=SIGDANO_New FREE=FreeR_flag F(+)=F_New(+)
>    SIGF(+)=SIGF_New(+) F(-)=F_New(+) SIGF(-)=SIGF_New(+)

[...]

>    /home/ajay/programs/ccp4/ccp4-6.2.0/lib/data/syminfo.lib
>     MTZ2VARIOUS:   *** You are inputting F(+) AND  FP  - incompatible ***

[...]

This just means you have to choose one of the sets {FP, SIGFP, DP,
SIGDP} or {F(+), F(-) SIGF(+), SIGF(-)} — you can’t have both.
-- 
Ian Clifton ⚗                 Phone: +44 1865 275677
Chemistry Research Laboratory Fax:   +44 1865 285002
Oxford University             [email protected]
Mansfield Road   Oxford OX1 3TA   UK