Dear Jens, did you try aimless instead of scala? I understood it is the successor of scala and I would not have thought scala is still being developed. Phil should correct me if I am wrong.
Best, Tim P.S.: I hope it will be a long time before the last release of ccp4. ;-) On 12/10/2013 05:05 AM, Jens Kaiser wrote: > Dear developers, > We have been doing the "local" scaling with scala of multiple > wavelengths for some time. We scaled one dataset collected remotely from > the absorption edge, and input this to scala as a reference as one batch > without any problems. With the latest release of CCP4, though, we get > the following error (reference dataset is assigned to batch 99999): > > **** Missing phi limits for batch 99999 > > > > **** No valid orientation data for batch 99999: this is not allowed > with > TAILS, SECONDARY, ABSORPTION or BEAMS options > > Scala: **** Failed in SETSCL **** > Times: User: 0.0s System: 0.0s Elapsed: 0:00 > > Our current workaround is to use the last, not the latest, release of > CCP4. > > Any help is appreciated, > > Jens > -- Dr Tim Gruene Institut fuer anorganische Chemie Tammannstr. 4 D-37077 Goettingen GPG Key ID = A46BEE1A