Dear Jens,

did you try aimless instead of scala? I understood it is the successor
of scala and I would not have thought scala is still being developed.
Phil should correct me if I am wrong.

Best,
Tim

P.S.: I hope it will be a long time before the last release of ccp4. ;-)

On 12/10/2013 05:05 AM, Jens Kaiser wrote:
> Dear developers,
>   We have been doing the "local" scaling with scala of multiple
> wavelengths for some time. We scaled one dataset collected remotely from
> the absorption edge, and input this to scala as a reference as one batch
> without any problems. With the latest release of CCP4, though, we get
> the following error (reference dataset is assigned to batch 99999):
> 
>  **** Missing phi limits for batch   99999
> 
> 
> 
>  **** No valid orientation data for batch  99999: this is not allowed
> with
> TAILS, SECONDARY, ABSORPTION or BEAMS options
> 
>  Scala:  **** Failed in SETSCL ****
> Times: User:       0.0s System:    0.0s Elapsed:     0:00
> 
> Our current workaround is to use the last, not the latest, release of
> CCP4.
> 
> Any help is appreciated,
> 
> Jens
> 

-- 