Hi Mahesh,

In the current version of phenix.refine contains the separate option for
> refinement: xyz (reciprocal space) and xyz (real space ).  What does it
> mean and how it differs from the previous versions which had xyz and real
> space instead.
>

All the same, different name. One refines model against Fobs, the other one
against 2mFo-DFc map (whole model and side chain rotamer fitting using grid
searches, if it is a protein).


> Can we run both of them simultaneously?
>

Both are enabled by default, so apparently the answer is yes.


> Is it advisable to do both refinement for DNA ?
>

Sure, why not?

Good luck!
Pavel

########################################################################