Hi All, there was a bug at some point that could potentially lead to this.
This all should be fixed in current Phenix nightly builds: http://phenix-online.org/download/nightly_builds.cgi If not, get back to us (phenixbb or Phenix help lists or reply directly to me). Pavel On Mon, Oct 19, 2020 at 11:52 AM Boniecki, Michal <michal.bonie...@usask.ca> wrote: > Hello, > I have a problem during refining with one of the Tyr residues. It is > constantly pushed out of the position during refinement in all 4 chains in > ASU. > I have tried to exclude it from refinement in phenix but it is refined > anyway out of the position with wrong geometry. Is there a possibility to > fix it during refinement? > The closest contact it has, is 2.4A between hydroxyl group and C=O of Pro, > but Tyr itself is inside hydrophobic cleft (Ile,Pro,Leu) > Thank You for all help. Stay safe, > Michal > > > ######################################################################## To unsubscribe from the CCP4BB list, click the following link: https://www.jiscmail.ac.uk/cgi-bin/WA-JISC.exe?SUBED1=CCP4BB&A=1 This message was issued to members of www.jiscmail.ac.uk/CCP4BB, a mailing list hosted by www.jiscmail.ac.uk, terms & conditions are available at https://www.jiscmail.ac.uk/policyandsecurity/