Hi All,

there was a bug at some point that could potentially lead to this.

This all should be fixed in current Phenix nightly builds:
http://phenix-online.org/download/nightly_builds.cgi

If not, get back to us (phenixbb or Phenix help lists or reply directly to
me).

Pavel

On Mon, Oct 19, 2020 at 11:52 AM Boniecki, Michal <michal.bonie...@usask.ca>
wrote:

> Hello,
> I have a problem during refining with one of the Tyr residues. It is
> constantly pushed out of the position during refinement in all 4 chains in
> ASU.
> I have tried to exclude it from refinement in phenix but it is refined
> anyway out of the position with wrong geometry. Is there a possibility to
> fix it during refinement?
> The closest contact it has, is 2.4A between hydroxyl group and C=O of Pro,
> but Tyr itself is inside hydrophobic cleft (Ile,Pro,Leu)
> Thank You for all help. Stay safe,
> Michal
>
>
>

########################################################################

To unsubscribe from the CCP4BB list, click the following link: