Hi Kyle,

get a second opinion. Phenix, Refmac, or Shelxl are your options. If you
refined your model with one of them, try another. If you choose
phenix.refine, let it find/build/refine waters automatically. This way, you
can rule out a bug in the software you used to obtain this result or
modeling error. Of course, if this happens with Phenix, feel free to send
me the files off-list, and I will have a close look!

Good luck!
Pavel


On Tue, Jan 6, 2026 at 6:48 AM Kyle Gregory <
[email protected]> wrote:

> Dear all,
>
> I have a 2.6 angstrom structure, which has 10 molecules in the ASU. I have
> modelled approx 200 water molecules. They fit spherical density nicely and
> make suitable contacts with the protein. The only problem is nearly every
> single water molecule has a lower B-factor than the protein atoms they
> coordinate. E.g protein atoms could be 30/40 while water is 16 angstrom^2.
>
> Does anyone have a suggestion as to why, and whether there are some things
> I should be trouble shooting?
>
> Kind regards,
> Kyle
>
> ------------------------------
>