On 05/24/2016 10:38 AM, Swift Griggs wrote:
Since I'm an igmo about most machines before the mid-eighties (and still
fuzzy even on most of those), I'm curious about all these older machines
with front panel buttons and switches. What all did they do? You could
actually program them using the front panel right? Some of them
bootstrapped this way, too? What kind of "language" was used for that
(ie.. what were the basic mechanics)? Did the buttons ever change color?
Were you considered a badass if you had switch flipping all memorized down
to an art? Were they mainly multi-position toggle switches or on/off
buttons?


The PDP-5 I did a fair bit of work on needed a bootstrap program loaded in from switches, it had no internal ROM for that. And, whenever a program crashed, it generally wiped the entire contents of memory, so the boot had to be reloaded by hand. We actually wore out the switches. It was about 15-20 12-bit words that needed to be entered. We had DECtape on that machine, so we generally entered to boot loader for that.

The LINC was also a 12-bit computer, but it had built-in boot hardware. it was not a boot loader program in a ROM, but when you pressed the load button, it would execute an I/O command from the left switches, and the right switches told it where to put it in memory. So, that was a big advance, a one-button boot.

You could use the switches to patch a program you were debugging, look at memory locations to examine temporary data values, etc.

A few machines had lighted switches. These would generally be white buttons with lamps behind them. The only one I know of that changed color was the power button ("key" in IBM-speak) on IBM 360's. It lit red while the power-up sequence was in progress, then turned white when all power supplies were up. IBM tape drives and disk drives had lighted buttons to show status, different color buttons and indicators gave them different colors, but they were generally just lit and unlit, but not multi-color.

DEC PDP machines generally had a few switches that were multi-position, Such as stop/single-step and load address/examine, otherwise they were all on-off.

IBM 360's had a row of switches that were multi-position, mostly for FE diagnostic purposes. The data and address switches were all on/off.

Jon