> On Jul 26, 2018, at 12:19 AM, Mattis Lind via cctalk <cctalk@classiccmp.org> 
> wrote:
> 
> You need to move the motor to a new position in the RK05. The drive is
> already prepared for all this. It is just the pulley, moving the motor and
> the 220VAC jumper that is needed.

I'm just working on my second RK05 drive now, to see if I can get it going by 
VCF West (I'm going to get crazy this year and rent a truck and show the 11/45, 
so some other people can enjoy it :-))

In any case, I can confirm that the power supply and transformers are 
jumper-able for 220VAC, and the motor is on a spring-tensioned swing arm, so it 
probably accommodates a different pulley just fine.  HOWEVER, I noticed today 
that my particular motor has an ominous bright orange sticker on it that 
explicitly says "60 Hz ONLY".  As far as I know, its an original motor.  FWIW!

https://drive.google.com/file/d/1ZpupgCaQ2InqQrv1uruBJPZZGlDUTuwW/view 
<https://drive.google.com/file/d/1ZpupgCaQ2InqQrv1uruBJPZZGlDUTuwW/view>

    cheers,
       --FritzM.


Reply via email to