Is it a switcher or an AC?
A custom transformer is going to be quite expensive. About the only way is to 
cannibalize another machine.
Dwight

________________________________
From: cctalk <[email protected]> on behalf of Mattis Lind via 
cctalk <[email protected]>
Sent: Sunday, September 29, 2019 11:44 PM
To: General Discussion: On-Topic and Off-Topic Posts <[email protected]>
Subject: IBM 5110 transformer?

A friend of mine is trying to repair a IBM 5110. He is convinced that the
transformer is bad.

Anyone knows the spec of the transformer?

Someone that has a spare?

Looking into the tech documentation tell me that the machine requires +/-
5V and +/- 12 V and also +8.5V

A very rough guesstimate based on the number of wires from the PSU to the
backplane would give 20A 5V, 4A +12V, 4A +8.5V, 1A -5V and 1A -12V.

Anyone with a better guess?

/Mattis

Reply via email to