On Tue, Nov 12, 2019 at 8:40 AM Jay Jaeger <[email protected]> wrote:
> According to the Fiche I have for ENKCC version 1.2 (Diagnostic Listing) > dated September 1982 - VAX 11/730 MCT MICRO > > Test 33: Moving Inversion Test on Array (M8728 ARRAY or M8391 MCT Module) > > Error 8: > > "Moving Inversion failed on descending path with background of 0's Bit > being toggled is either bit 0 or bit 1" > > "If a failure occurs the address being accessed will be in LS 9 and can > be examined via EX LS 9. The bit being toggled at the maxiumum rate > will be in WR 3 and can be examined by typing EX WR 3. OTHER data is > not used so as to insure that the test runs as fast as possible." > Thanks, Jay! Any chance of getting these scanned at some point? To the best of my knowledge these listings haven't been archived anywhere. - Josh