Intermittent power supply problem? 

Sent from my iPhone

> On Aug 11, 2022, at 10:55, David Glover-Aoki via cctalk 
> <[email protected]> wrote:
> 
> I have a recently recapped SE/30, and I have installed a SCSI2SD (v5.0a) 
> inside it. I don't have a (working) CD drive, and the floppy drive is broken, 
> so I configured SCSI device 3 to be a CD-ROM drive, and put the System 7.5.3 
> installer inside it, along with a copy of the patched "HD SC Setup" utility, 
> so I can format the other SCSI devices, which are configured as 2GB hard 
> disks.
> 
> Booting from the "CD" works fine. Formatting the disks works fine.
> 
> I cannot get the System 7.5.3 installer to complete. After copying a few 
> files, it complains that an error occurred, and then aborts.
> 
> Additionally, if I attempt to copy the contents of the "CD" to a hard disk, 
> after copying a few files, I get an error that says a "disk error" occurred. 
> It's not the same file every time, it copies a random number of files 
> successfully before erroring.
> 
> I've have also had a few random bomb errors, although these do not happen 
> reliably and I haven't managed to come up with a way of causing them on 
> demand. They may have stopped after I swapped the RAM, although that is 
> speculation.
> 
> Things that I have tried:
> 
> * Playing with the "SCSI Host", "SCSI Selection Delay", "Enable Parity", 
> "Respond to short SCSI selection pulses" settings on the SCSI2SD. No 
> combination seems to make any noticeable difference.
> 
> * Swapping out the RAM on the SE/30. I initially thought the RAM was bad, but 
> I replaced it with a different set and the symptoms are exactly the same.
> 
> * Removing the case back, in case something was overheating inside.
> 
> * Replacing the microSD card with a different one.
> 
> None of these have altered the symptoms at all, and I'm running out of ideas. 
> Any suggestions would be very welcome.
> 
> David
> 

Reply via email to