You may want to look around inside for seized fans. S/38s typically ran 7/24 and when turned off one or more fans would fail to start when the system was restarted.  Another thing to check would be the motor on the on the 72MD diskette drive.  My experience when servicing S/38 was  whenever I wanted to run diagnostics from diskettes I would first have to free up or replace the motor.  Like a usual 8" diskette drive the spindle motor is an AC motor that is powered whenever the system is turned on.  Most customers rarely used the diskette drive so did not notice it was seized.

My recollection is the logic in the systems is solid, perhaps the weakest part is the 62PC (Piccolo) disk unit inside that stored the  systems microcode. Most customers isolated it from the storage pool so they would not have to reload the entire system when it packed it in.

What do you have for storage on the system?  Originally the systems supported multiple 62PCs inside or 3370s (the controller is not the same as the one used on 370s)  Later there was an option offered to support attachment of 9332 or 9335 disks.  The 9332 200 and 400 are probably the most robust of the lot.

Paul.