Hello
        Could someone tell me what is wrong with my Yamaha 4116S/ It was
working fine until last week.  cdrecord has been recently updated to 10a4.

Starting new track at sector: 0
CDB:  2A 00 00 00 10 D0 00 00 10 00
cdrecord: Input/output error. write_g1: scsi sendcmd: retryable error
Sense Bytes: 70 00 04 D0 00 00 00 0A 00 00 00 00 09 02 00 00
status: 0x2 (CHECK CONDITION)
Sense Key: 0x4 Hardware Error, Segment 0
Sense Code: 0x09 Qual 0x02 (focus servo failure) Fru 0x0
Sense flags: Blk -805306368 (not valid)

write track data: error after 8814592 bytes
Sense Bytes: 70 00 00 00 00 00 00 0A 00 00 00 00 00 00 00 00 00 00
Writing  time:   69.670s
Fixating...
Fixating time:    9.190s
cdrecord: fifo had 461 puts and 270 gets.

Thanks a lot.

Eduardo


--  
To UNSUBSCRIBE, email to [EMAIL PROTECTED]
with a subject of "unsubscribe". Trouble? Contact [EMAIL PROTECTED]

Reply via email to