Matthias Andree <[EMAIL PROTECTED]> wrote: > Greeting, > > running a C2 scan on an audio CD in a NEC ND-4550A (FW rev. 1.07) causes > errors like these, where a C2 scan of the same CD in a Plextor > PX-W4824TA (FW rev. 1.06) on the same ATA cable succeeds. > > Read speed: 7056 kB/s (CD 40x, DVD 5x). > Write speed: 2822 kB/s (CD 16x, DVD 2x). > Capacity: 202390 Blocks = 404780 kBytes = 395 MBytes = 414 prMB > Sectorsize: 2048 Bytes > Copy from SCSI (1,0,0) disk to file '/dev/null' > end: 202390 > readcd: Success. read_cd: scsi sendcmd: no error > CDB: BE 00 00 00 00 31 00 00 31 FA 00 00 > status: 0x2 (CHECK CONDITION) > Sense Bytes: 70 00 04 00 00 00 00 0A 00 00 00 00 08 00 00 00 > Sense Key: 0x4 Hardware Error, Segment 0 > Sense Code: 0x08 Qual 0x00 (logical unit communication failure) Fru 0x0 > Sense flags: Blk 0 (not valid) > resid: 123748 > cmd finished after 6.422s timeout 40s > readcd: Success. Cannot read source disk > readcd: Retrying from sector 49.
Did you try this on a platform that is known to work? If not, first try SchilliX ftp://ftp.berlios.de/pub/schillix/ This looks like a bug caused by a DMA implementation bug in your OS in case it is not caused by an internal malfunction of the drive. Jörg -- EMail:[EMAIL PROTECTED] (home) Jörg Schilling D-13353 Berlin [EMAIL PROTECTED] (uni) [EMAIL PROTECTED] (work) Blog: http://schily.blogspot.com/ URL: http://cdrecord.berlios.de/old/private/ ftp://ftp.berlios.de/pub/schily -- To UNSUBSCRIBE, email to [EMAIL PROTECTED] with a subject of "unsubscribe". Trouble? Contact [EMAIL PROTECTED]