Thanks for the suggestions. Looks like I am indeed wearing out the media by too many (95 seems to be the limit at least for this media) sessions. Examining the error codes further (3 73 02 is SCSI error POWER CALIBRATION AREA IS FULL) shows that there is a physical limitation on the number of sessions (or calibrations in this case) that can be done. I am now writing larger files in fewer sessions and have so far had a better luck.
Cheers Farshad -- To UNSUBSCRIBE, email to [EMAIL PROTECTED] with a subject of "unsubscribe". Trouble? Contact [EMAIL PROTECTED]