On Friday, September 23, 2011 04:29:39 PM Paras pradhan wrote:
> This is a SAN drive mounted. I have checked with my storage
> administrator if this has been re mapped or any similar events and he
> verified that nothing has happened...(I trust him)

May I ask what sort of SAN?  Fibre Channel or iSCSI?  Are there any access 
controls (such as EMC's Access Logix or zoning in the switch) in place to 
prevent multiple initiators connecting to a particular LUN?

SAN attachment mildly complicates things; I've seen some odd LUN reshuffling 
before, but it was an older FLARE than what I'm currently running on our 
Clariions and it was something that was a corner case but was fixed in a later 
NDU, and it had to do with Access Logix (I don't remember the Primus number 
right off, as it has been several years now).  

If the SAN OS keeps event logs you could try to correlate with the event; 
beyond that you may just have to do some testing.

As you say, someone somewhere had to do a repartition; the hard part is 
determining where the error is.  Good luck.
_______________________________________________
CentOS mailing list
CentOS@centos.org
http://lists.centos.org/mailman/listinfo/centos

Reply via email to