On 02/05/12 3:24 PM, Ross Walker wrote:
> It might be easier to do the striping in software cause that's a zero 
> over-head operation and it makes the hardware RAID easier to setup, maintain 
> and can make rebuilds less painful depending on the controller.

I just tried a bunch of combinations on a 3 x 11 raid60 configuration 
plus 3 global hotspares, and decided that letting the controller (LSI 
9260-8i MegaSAS2) do it was easier all the way around.   of course, with 
other controllerrs, your mileage may vary.  and yes, megacli64 is an 
ugly tool to tame.

with 3TB SAS drives, single drive failures rebuild in 12 hours, double 
failures in 18 hours.  (failures forced by disabling drives via megacli)



-- 
john r pierce                            N 37, W 122
santa cruz ca                         mid-left coast

_______________________________________________
CentOS mailing list
CentOS@centos.org
http://lists.centos.org/mailman/listinfo/centos