Hi everybody,
I'm using ceph with ceph-fuse client.
I have the same problem with version 0.36 or the new 0.37.
I use ext4 as filesystem for OSDs partition.
I have an application creating around 200 files for a total size around 40G :
du -sh /tmp/ceph/cmorandi/
37G /tmp/ceph/cmorandi/
When I delete everything in this directory, the size with du is ok :
du -sh /tmp/ceph/cmorandi/
512 /tmp/ceph/cmorandi/
But the df -h on the ceph mount show exactly the same amount of used space.
'ceph pg stat' give exactly the same number for data before and after deletion:
[root@node91 ~]# ceph pg stat
2011-10-19 14:59:56.263368 mon <- [pg,stat]
2011-10-19 14:59:56.263910 mon.1 -> 'v6382: 792 pgs: 792 active+clean; 228 GB
data, 229 GB used, 90122 MB / 334 GB avail' (0)
[root@node91 ~]# ceph pg stat
2011-10-19 15:01:56.157879 mon <- [pg,stat]
2011-10-19 15:01:56.158889 mon.1 -> 'v6382: 792 pgs: 792 active+clean; 228 GB
data, 229 GB used, 90122 MB / 334 GB avail' (0)
If I stop, then start everything /etc/init.d/ceph -a [stop,start], the space is
freed:
2011-10-19 15:29:23.189312 pg v6407: 792 pgs: 792 active+clean; 210 GB data,
211 GB used, 105 GB / 334 GB avail
Below the OSDs disk usage before and after restart :
root@node0:~ # for i in {92..95};do ssh node$i "df -h /dev/sda5";done
Filesystem Size Used Avail Use% Mounted on
/dev/sda5 84G 57G 23G 72% /data/osd.0
Filesystem Size Used Avail Use% Mounted on
/dev/sda5 84G 47G 33G 59% /data/osd.1
Filesystem Size Used Avail Use% Mounted on
/dev/sda5 84G 56G 24G 71% /data/osd.2
Filesystem Size Used Avail Use% Mounted on
/dev/sda5 84G 71G 8.8G 89% /data/osd.3
root@node0:~ # for i in {92..95};do ssh node$i "df -h /dev/sda5";done
Filesystem Size Used Avail Use% Mounted on
/dev/sda5 84G 52G 28G 66% /data/osd.0
Filesystem Size Used Avail Use% Mounted on
/dev/sda5 84G 43G 37G 55% /data/osd.1
Filesystem Size Used Avail Use% Mounted on
/dev/sda5 84G 52G 28G 65% /data/osd.2
Filesystem Size Used Avail Use% Mounted on
/dev/sda5 84G 66G 15G 83% /data/osd.3
I can reproduce it if needed.
I want to know if the problem might be related to a misconfiguration or if it
sounds more like a bug ?
Sincerely,
--
Cédric Morandin - OASIS Research Team
INRIA Sophia Antipolis
2004 route des lucioles - BP 93
06902 Sophia-Antipolis (France)
Phone: +33 4 97 15 53 89
--
To unsubscribe from this list: send the line "unsubscribe ceph-devel" in
the body of a message to [email protected]