Hi,
On 12/23/2011 08:21 AM, [email protected] wrote:
Hi, all:
I am curious about why ceph cluster only support odd number monitors.
It doesn't only support a odd number. A even number of monitors works in
theory, but it's recommended to use a odd number to get a majority.
If we lose 1 monitor (becomes odd number),
You shouldn't look to the number of online monitors, but to the number
of monitors in your monmap. That should be a odd number.
Wido
would it cause any problem if we do not handle this situation in short
time?
Thanks!
--
To unsubscribe from this list: send the line "unsubscribe ceph-devel" in
the body of a message to [email protected]
More majordomo info at http://vger.kernel.org/majordomo-info.html
--
To unsubscribe from this list: send the line "unsubscribe ceph-devel" in
the body of a message to [email protected]
More majordomo info at http://vger.kernel.org/majordomo-info.html