Hi,
  We did a simple throughput test on Ceph with 2 OSD nodes configured
with one replica policy. For each OSD node, the throughput measured by 'dd' run locally is 117MB/s. Therefore, in theory, the two OSDs could provide 200+MB/s throughput. However, using 'iozone' from clients we only get a peak throughput at around 40MB/s. Is that because a write will incur 2 replica * 2 journal write? That is, writing into journal
and replica doubled the traffic, respectively, which results in a total
4x write amplification. Is that true, or our understanding is wrong,
and some performance tuning hint?

Cheers,
Li Wang


--
To unsubscribe from this list: send the line "unsubscribe ceph-devel" in
the body of a message to [email protected]