On Mon, Sep 14, 2015 at 7:56 PM, [email protected] <[email protected]> wrote: > The OSD is supposed to stay down if any of the networks are missing. > ----------------osd1 osd2 osd3,if cut off osd2's cluster-network,then all of > the osd( osd1/osd2/osd3) will all stay down?
No, but osd2 should stay down. If we've failed with this (...again...) it'll need fixing. > Ceph is a CP system in CAP parlance; there's no such thing as a CA system. ;) > > What version of Ceph are you testing right now?-------------- ceph > version:0.94.2 > -Greg -- To unsubscribe from this list: send the line "unsubscribe ceph-devel" in the body of a message to [email protected] More majordomo info at http://vger.kernel.org/majordomo-info.html