Thank you, Konstantin.
I'll resize the rocksDB devices then and see what happens if we turn the warnings back on.

Thanks!
Eugen


Zitat von Konstantin Shalygin <[email protected]>:

On 9/26/19 9:45 PM, Eugen Block wrote:
I'm following the discussion for a tracker issue [1] about spillover warnings that affects our upgraded Nautilus cluster. Just to clarify, would a resize of the rocksDB volume (and expanding with 'ceph-bluestore-tool bluefs-bdev-expand...') resolve that or do we have to recreate every OSD?

Yes, this works since Luminous 12.2.11



k


_______________________________________________
ceph-users mailing list -- [email protected]
To unsubscribe send an email to [email protected]

Reply via email to