Hi Samuel, I'm using Octopus. If it is the release problem, why it is successful with only ms_async_rdma_device_name and ms_async_rdma_gid_idx?
Best regards, On Sat, Sep 19, 2020 at 3:33 PM [email protected] <[email protected]> wrote: > Which Ceph version are you using? Just wondering Ceph RDMA support is > officially announced, or still on development? > > best regards, > > samuel > > ------------------------------ > [email protected] > > > *From:* Lazuardi Nasution <[email protected]> > *Date:* 2020-09-18 19:21 > *To:* ceph-users <[email protected]> > *Subject:* [ceph-users] Ceph RDMA GID Selection Problem > Hi, > > I have something weird about GID selection for Ceph with RDMA. When I do > configuration with ms_async_rdma_device_name and ms_async_rdma_gid_idx, > Ceph with RDMA running successfully. But, when I do configuration with > ms_async_rdma_device_name, ms_async_rdma_local_gid and > ms_async_rdma_roce_ver, Ceph with RDMA is not working, OSDs are down in > seconds after they up. The GID index which is used on the first attempt is > associated with the GID and RoCE version which are used on the second > attempt. Is this the string matter (maybe because GID is using colon > characters) or something else? Using the GID index sometimes gives me > problems due to it not persisting and changes happen every time I do > network reconfiguration (for example: adding/removing VLAN), or even > rebooting. > > Best regards, > _______________________________________________ > ceph-users mailing list -- [email protected] > To unsubscribe send an email to [email protected] > > > _______________________________________________ ceph-users mailing list -- [email protected] To unsubscribe send an email to [email protected]