On 28/01/2026 09:17, Janek Bevendorff via ceph-users wrote:
I just noticed that this applies to RBD clients as well. How is this supposed to work? Can you use only radosgw and ceph-fuse if you want to use upmap-read? It seems strange to me that the most central Ceph systems don't work with these new features.On 26/01/2026 18:55, Janek Bevendorff via ceph-users wrote:Hi,Is there a way to use the new upmap-read balancer mode when I have CephFS kernel clients connected? Our cluster runs Squid and all connected clients are on kernel 6.11-6.14, so they should be new enough. However, they identify themselves as luminous (I could not find clear documentation about this, but this seems to be hard-coded and by design), so I cannot run ceph osd set-require-min-compat-client reef, which is required for the balancer module to work.I have 500 clients connected and migrating them all to FUSE would be a headache. Is there a way around that? Some of my pools have extremely high read balance scores and we're also struggling with performance issues as a result.Janek _______________________________________________ ceph-users mailing list -- [email protected] To unsubscribe send an email to [email protected]_______________________________________________ ceph-users mailing list -- [email protected] To unsubscribe send an email to [email protected]
-- Bauhaus-Universität Weimar Bauhausstr. 9a, R308 99423 Weimar, Germany Phone: +49 3643 58 3577 www.webis.de