Hi,
I attached one 500G block device to the vm, and test it in vm use
"dd if=/dev/zero of=myfile bs=1M count=1024" ,
Then I got a average io speed about 31MB/s. I thought that i
should have got 100MB/s,
cause my vm hypervisor has 1G nic and osd host has 10G nic。
Did i got a wrong result? how can i make it faster?
Your sincerely,
Michael.
[root@storage1 ~]# ceph -w
2014-03-16 17:24:44.596903 mon.0 [INF] pgmap v2245: 1127 pgs: 1127
active+clean; 8758 MB data, 100 GB used, 27749 GB / 29340 GB avail; 5059
kB/s wr, 1 op/s
2014-03-16 17:24:45.742589 mon.0 [INF] pgmap v2246: 1127 pgs: 1127
active+clean; 8826 MB data, 100 GB used, 27749 GB / 29340 GB avail; 21390
kB/s wr, 7 op/s
2014-03-16 17:24:46.864936 mon.0 [INF] pgmap v2247: 1127 pgs: 1127
active+clean; 8838 MB data, 100 GB used, 27749 GB / 29340 GB avail; 36789
kB/s wr, 13 op/s
2014-03-16 17:24:49.578711 mon.0 [INF] pgmap v2248: 1127 pgs: 1127
active+clean; 8869 MB data, 100 GB used, 27749 GB / 29340 GB avail; 11404
kB/s wr, 3 op/s
2014-03-16 17:24:50.824619 mon.0 [INF] pgmap v2249: 1127 pgs: 1127
active+clean; 8928 MB data, 100 GB used, 27749 GB / 29340 GB avail; 22972
kB/s wr, 7 op/s
2014-03-16 17:24:51.980126 mon.0 [INF] pgmap v2250: 1127 pgs: 1127
active+clean; 8933 MB data, 100 GB used, 27749 GB / 29340 GB avail; 28408
kB/s wr, 10 op/s
2014-03-16 17:24:54.603830 mon.0 [INF] pgmap v2251: 1127 pgs: 1127
active+clean; 8954 MB data, 100 GB used, 27749 GB / 29340 GB avail; 7090
kB/s wr, 2 op/s
2014-03-16 17:24:55.671644 mon.0 [INF] pgmap v2252: 1127 pgs: 1127
active+clean; 9034 MB data, 100 GB used, 27749 GB / 29340 GB avail; 27465
kB/s wr, 9 op/s
2014-03-16 17:24:57.057567 mon.0 [INF] pgmap v2253: 1127 pgs: 1127
active+clean; 9041 MB data, 100 GB used, 27749 GB / 29340 GB avail; 39638
kB/s wr, 13 op/s
2014-03-16 17:24:59.603449 mon.0 [INF] pgmap v2254: 1127 pgs: 1127
active+clean; 9057 MB data, 100 GB used, 27749 GB / 29340 GB avail; 6019
kB/s wr, 2 op/s
2014-03-16 17:25:00.671065 mon.0 [INF] pgmap v2255: 1127 pgs: 1127
active+clean; 9138 MB data, 100 GB used, 27749 GB / 29340 GB avail; 25646
kB/s wr, 9 op/s
2014-03-16 17:25:01.860269 mon.0 [INF] pgmap v2256: 1127 pgs: 1127
active+clean; 9146 MB data, 100 GB used, 27749 GB / 29340 GB avail; 40427
kB/s wr, 14 op/s
2014-03-16 17:25:04.561468 mon.0 [INF] pgmap v2257: 1127 pgs: 1127
active+clean; 9162 MB data, 100 GB used, 27749 GB / 29340 GB avail; 6298
kB/s wr, 2 op/s
2014-03-16 17:25:05.662565 mon.0 [INF] pgmap v2258: 1127 pgs: 1127
active+clean; 9274 MB data, 101 GB used, 27748 GB / 29340 GB avail; 34520
kB/s wr, 12 op/s
2014-03-16 17:25:06.851644 mon.0 [INF] pgmap v2259: 1127 pgs: 1127
active+clean; 9286 MB data, 101 GB used, 27748 GB / 29340 GB avail; 56598
kB/s wr, 19 op/s
2014-03-16 17:25:09.597428 mon.0 [INF] pgmap v2260: 1127 pgs: 1127
active+clean; 9322 MB data, 101 GB used, 27748 GB / 29340 GB avail; 12426
kB/s wr, 5 op/s
2014-03-16 17:25:10.765610 mon.0 [INF] pgmap v2261: 1127 pgs: 1127
active+clean; 9392 MB data, 101 GB used, 27748 GB / 29340 GB avail; 27569
kB/s wr, 13 op/s
2014-03-16 17:25:11.943055 mon.0 [INF] pgmap v2262: 1127 pgs: 1127
active+clean; 9392 MB data, 101 GB used, 27748 GB / 29340 GB avail; 31581
kB/s wr, 16 op/s
[root@storage1 ~]# ceph -s
cluster 3429fd17-4a92-4d3b-a7fa-04adedb0da82
health HEALTH_OK
monmap e1: 1 mons at {storage1=193.168.1.100:6789/0}, election epoch
1, quorum 0 storage1
osdmap e245: 16 osds: 16 up, 16 in
pgmap v2273: 1127 pgs, 4 pools, 9393 MB data, 3607 objects
101 GB used, 27748 GB / 29340 GB avail
1127 active+clean
[root@storage1 ~]# ceph osd tree
# id weight type name up/down reweight
-1 16 root default
-2 16 host storage1
0 1 osd.0 up 1
1 1 osd.1 up 1
2 1 osd.2 up 1
3 1 osd.3 up 1
4 1 osd.4 up 1
5 1 osd.5 up 1
6 1 osd.6 up 1
7 1 osd.7 up 1
8 1 osd.8 up 1
9 1 osd.9 up 1
10 1 osd.10 up 1
11 1 osd.11 up 1
12 1 osd.12 up 1
13 1 osd.13 up 1
14 1 osd.14 up 1
15 1 osd.15 up 1
--------------------------------------------------------
ZTE Information Security Notice: The information contained in this mail (and
any attachment transmitted herewith) is privileged and confidential and is
intended for the exclusive use of the addressee(s). If you are not an intended
recipient, any disclosure, reproduction, distribution or other dissemination or
use of the information contained is strictly prohibited. If you have received
this mail in error, please delete it and notify us immediately.
<<image/gif>>
<<image/gif>>
_______________________________________________ ceph-users mailing list [email protected] http://lists.ceph.com/listinfo.cgi/ceph-users-ceph.com