On 07/06/2014 02:42 PM, Lazuardi Nasution wrote:
Hi,

Is it possible to combine MDS and MON or OSD inside the same node? Which
one is better, MON with MDS or OSD with MDS?


Yes, not a problem. Be aware, the MDS can be memory hungry depending on your active data set.

There is no golden rule for mixing daemons however.

CephFS is not stable yet however, keep that in mind!

How do I configure OSD and MDS to allow two kind of public network
connections, standard (1 GbEs) and jumbo (10 GbEs). I want to take
advantage of jumbo frame for some supported clients.

That's not possible. There can only be one public network, so your idea is not feasible.


Best regards,



_______________________________________________
ceph-users mailing list
[email protected]
http://lists.ceph.com/listinfo.cgi/ceph-users-ceph.com



--
Wido den Hollander
42on B.V.
Ceph trainer and consultant

Phone: +31 (0)20 700 9902
Skype: contact42on
_______________________________________________
ceph-users mailing list
[email protected]
http://lists.ceph.com/listinfo.cgi/ceph-users-ceph.com

Reply via email to